Internal Health Led is red on HP ProLiant Server post Error: 1610-Temperature violation detected The description of Internal health LED status Green = Normal Amber = System degraded. Refer to system board LEDs to identify component in degraded state. Red = System critical. Refer to system board LEDs to identify component in critical state. Troubleshooting: 1. Run HP System Management Homepage to check any errors. 2. Run HP Integrated Management log Viewer to check any errors. 3. Check Windows Event Viewer for any errors. Case 1: The server room was too hot and the server shutdown unexpected. The HP Integrated Management log Viewer displays "post Error: 1610-Temperature violation detected". Resolution: cool the temperature and restart the server. Case 2: The server Internal Health Led is red and the HP Integrated Management log Viewer displays "post Error: 1610-Temperature violation detected". Resolution: Rebooting the server displays fan failed. Also open the cover, the fan 2 light is red. Replaced it. Post your questions, comments, feedbacks and suggestions Related Topics |
|
|
|