Troubleshooting Operations Manager Event ID 20070 and 20016

Situation: When install SCOM Agent on an untrusted computer, you may receive these events:

Log Name:      Operations Manager

Source:        OpsMgr Connector

Event ID:      20070

Description: The OpsMgr Connector connected to FQND, but the connection was closed immediately after authentication occurred.  The most likely cause of this error is that the agent is not authorized to communicate with the server, or the server has not received configuration.  Check the event log on the server for the presence of 20000 events, indicating that agents which are not approved are attempting to connect.

Event ID:      21016

Description: OpsMgr was unable to set up a communications channel to FQDN and there are no failover hosts.  Communication will resume when FQDN is available and communication from this computer is allowed.

Troubleshooting: If you just imported CA and untrusted client certificates on the untrusted computer, restart al SCOM service on SCOM Server. That should fix the problem and the Event Viewer will show Event ID: 21019

Description:

OpsMgr has returned to communicating with it’s primary host FQDN.

Published by

Bob Lin

Bob Lin, Chicagotech-MVP, MCSE & CNE Data recovery, Windows OS Recovery, Networking, and Computer Troubleshooting on http://www.ChicagoTech.net How to Install and Configure Windows, VMware, Virtualization and Cisco on http://www.HowToNetworking.com